Lead-lined doors, also named X-Ray Doors, are specially designed to provide radiation protection in various settings, such as hospitals, laboratories, and industrial facilities. These doors feature a core of lead sheets, ensuring safety by preventing the harmful effects of radiation leakage. Applications include X-ray rooms, radiology departments, nuclear medicine facilities, and industrial testing areas. With a range of customizable sizes and finishes, lead-lined doors are vital for maintaining safety and compliance in radiation-heavy environments.
Rax lead-lined doors offer exceptional quality and performance, ensuring a secure barrier against radiation. With precision engineering and robust construction, these doors provide excellent shielding in even the most demanding applications. Customers praise Rax Door’s commitment to durability, ease of installation, and aesthetic appeal. Their doors are suitable for various industries, proving to be a reliable choice for radiation protection.
Your Premier Manufacturer Of Lead Lined Door
RAX Doors is a leading manufacturer of premium-quality lead-lined doors, dedicated to providing innovative radiation shielding solutions for healthcare and industrial sectors. Our expertise and commitment to excellence set us apart in the market.
Advantages of choosing RAX Door:
Customization: Tailor-made solutions for diverse applications
Quality: Manufactured to meet strict industry standards
Expertise: In-depth knowledge of radiation shielding requirements
Durability: Long-lasting and robust construction
Support: Comprehensive after-sales service and technical assistance
Comprehensive Guide to Lead-Lined Doors for Buyers
As a wholesale buyer, you need a thorough understanding of lead-lined doors to make informed purchasing decisions.
What are Lead-Lined Doors?
Lead-lined doors are specialized doors designed to provide protection against ionizing radiation, such as X-rays and gamma rays. They are constructed with a lead core or lead sheeting integrated into the door leaf and the door frame, effectively blocking the passage of harmful radiation. Lead-lined doors are an essential component of radiation protection in various facilities, ensuring the safety of staff, patients, and the general public.
Specifications and Standards
When selecting a lead-lined door, it is crucial to ensure that it complies with the relevant standards and specifications:
Radiation protection levels: The thickness of the lead lining in the door should be determined based on the required level of radiation protection. Common lead thicknesses range from 1mm to 3mm, but higher levels are available for specific applications.
Fire resistance: Some lead-lined doors are also designed to offer fire resistance, meeting standards such as BS 476 or EN 1634-1. These doors should be chosen for settings where both radiation protection and fire resistance are essential.
Acoustic performance: Lead-lined doors can also provide sound insulation, with ratings of up to 45dB Rw. This can be particularly useful in medical imaging rooms where quiet environments are necessary.
Durability: The door’s construction and materials should ensure a long service life. Steel doors with a powder-coated finish, for example, offer excellent durability and corrosion resistance.
Customization and Options
Lead-lined doors can be customized to meet specific project requirements:
Size: Lead-lined doors can be made in various sizes to fit a range of opening dimensions.
Finishes: Doors can be finished in a range of colors and materials to match the aesthetic of the facility.
Hardware: A variety of hardware options, such as panic bars, electronic access control, or automatic door openers, can be incorporated to suit different applications.
Additional features: Doors can also include features such as kick plates, push plates, or door closers, depending on the requirements of the facility.
Installation and Maintenance
Proper installation and maintenance are vital to ensure the longevity and performance of lead-lined doors:
Installation: Professional installation is crucial for maintaining the integrity of the radiation protection. Installers should be experienced in handling lead-lined doors and familiar with the specific requirements of radiation shielding.
Alignment: Ensuring correct alignment of the door and frame is essential for optimal radiation protection. A poorly aligned door can compromise the shielding effectiveness and pose a safety risk.
Inspection: Regular inspection of the door, frame, and hardware is necessary to identify any potential issues or signs of wear. Particular attention should be paid to the hinges, seals, and lead lining, as these components directly impact the door’s radiation protection capabilities.
Maintenance: Periodic maintenance, such as lubricating hinges and adjusting door closers, can help to extend the door’s service life and maintain its performance.
A Lead-Lined Door Manufacturer
RAX Door has established itself as a premier manufacturer of lead-lined doors, offering a wide range of products that meet and exceed industry standards. Our state-of-the-art manufacturing processes and stringent quality control measures ensure that our doors provide the highest level of radiation protection, fire resistance, and durability.
As a wholesale buyer, you can trust RAX Door to provide you with top-quality lead-lined doors, tailored to your specific needs. Our experienced team of professionals will work closely with you to understand your project requirements, offering expert advice and support throughout the process. When you partner with RAX Door, you are investing in the safety and well-being of your facility and its occupants.
FAQs
What materials are used in the construction of lead-lined doors?
Lead-lined doors are typically constructed from a steel or timber framework, filled with a lead core. The door frames are made from steel, and their inner surfaces are lined with lead sheets.
How thick should the lead lining be in a lead-lined door?
The thickness of the lead lining depends on the required level of radiation protection. Common lead thicknesses range from 1mm to 3mm, but higher levels are available for specific applications.
Can lead-lined doors also provide fire resistance and sound insulation?
Yes, some lead-lined doors are designed to offer fire resistance, meeting standards such as BS 476 or EN 1634-1. They can also provide sound insulation, with ratings of up to 45dB Rw.
Are lead-lined doors customizable?
Yes, lead-lined doors can be customized in terms of size, finishes, hardware, and additional features to meet specific project requirements.
What factors should be considered when selecting a lead-lined door?
When selecting a lead-lined door, consider factors such as radiation protection levels, fire resistance, acoustic performance, durability, and customization options to suit your specific project requirements.